DXCA55VSA CONTROL AND PARTS SET
Parts List
Notes: PWB1, PWB1 - CONTROL PCB
Notes: NOT AVAILABLE
Notes: PWB2, IPM/TRANSISTOR SOLD SEPERATELY - PWB2 - INVERTER BOARD - CONFIRM MODEL & SERVICE CODE - "FDCA160VS" has different boards
Notes: PWB3, NOISE FILTER. SCREW FOR TERMINAL IS PART NUMBER SSA912B105B. 2 electromagnetic coils
Notes: PWB4, POWER BOARD. COMES WITH 2 SMALL FUSES.
Notes: PWB, Demand Response Enabling Device. Only required if wired-in on installation. FOR MORE INFORMATION DISCUSS WITH TECH SUPPORT
Notes: TB1
Notes: TB
Notes: 52X1-1,1-2,2-1,2-2, 52X1/ LENGTH 7CM
Notes: R1-1,2,R2-1,2, SOLD INDIVIDUALLY - 15 Ohm
Notes: C1,2, C1 400V 3900MF
Notes: R1-3,4,R2-3,4, SOLD INDIVIDUALLY - 30 kO (kilo-Ohm)/ LENGTH 4.7CM
Notes: TM, IPM, Comes with heat paste and screws
Notes: 1250v 2.2uf. ***SOLD INDIVIDUALLY***
Notes: DM
Notes: L1-1,2,3, L1
Notes: 52X1-1,1-2,2-1,2-2, 52X1,52X2 - 200-240VAC ***SOLD INDIVIDUALLY***
Notes: THO-A,S,D,R1, THO-A,S,D,R1 - / LENGTH 193CM
Notes: THO-H, THO-H / LENGTH 133CM (compressor dome)
Notes: THO-R2
Notes: PWB3 L1o,PWB3 No,PWB3 L2o- PWB1 CNW,PWB4 CNW1, COMES WITH 5A FUSE. PWB3 L1o,PWB3 No,PWB3 L2o- PWB1 CNW,PWB4 CNW1
Notes: 5A
Notes: PWB1 CNM- 52X2 5,52X2 6, PWB1 CNM- 52X2 5,52X2 6. 2 BLACK WIRES, ONE SIDE IS PLUG, OTHER SIDE IS 2 LUGS. NEAR THE LUGS ARE WRITTEN ON THE WIRES "2-5" AND THE OTHER "2-6"
Notes: PWB1 CNI1- PWB2 CNI2
Notes: 52X1 5,52X1 6- PWB2 CNR
Notes: IPM P,IPM N- PWB2 CAN
Notes: PWB1 CNA2- PWB4 CNA3, PWB1 CNA2- PWB4 CNA3/ LENGTH 21.5CM
Notes: PWB1 CNA1- PWB4 CNA4, PWB1 CNA1- PWB4 CNA4/ LENGTH 23.5CM
Notes: PWB3 No,E-PWB3 CN1, PWB3 No,E- PWB3 CN/ LENGTH 29.5CM
Notes: TB1 N,PWB1 CNW2- TB2 2,TB2 3
Notes: PWB1 CNM- 52X2 5,52X2 6
Notes: TB2 D1,TB2 D2,TB2 D3,TB2 C,E- PWB5 CNDRED
Notes: PWB5 CNDRM- PWB1 CNDRM
Notes: FOR SENSOR, 1pc ONLY
SKU: DXCA55VSA CONTROL AND PARTS SET